Halogenated vent stream?Net heating value(MJ/scm)bVent stream flow rate (scm/min)cValues of terms for TRE equation: TRE = A * [ B + C + D + E + F ]Equation number
ABCDE | F
Yes0≤H ≤3.5Q <14.21/ETOC30.96334 | 0 | 0 | −0.13064QH | 0 | 1
14.2≤Q ≤18.81/ETOC19.1837 | 0.27580Q | 0.757620Q0.88 | −0.13064QH | 0.01025Q0.5 | 2
18.8<Q ≤6991/ETOC20.00563 | 0.27580Q | 0.303870Q0.88 | −0.13064QH | 0.01025Q0.5 | 3
699<Q ≤14001/ETOC39.87022 | 0.29973Q | 0.303870Q0.88 | −0.13064QH | 0.01449Q0.5 | 4
1400<Q ≤21001/ETOC59.73481 | 0.31467Q | 0.303870Q0.88 | −0.13064QH | 0.01775Q0.5 | 5
2100<Q ≤28001/ETOC79.59941 | 0.32572Q | 0.303870Q0.88 | −0.13064QH | 0.02049Q0.5 | 6
2800<Q ≤35001/ETOC99.464 | 0.33456Q | 0.303870Q0.88 | −0.13064QH | 0.02291Q0.5 | 7
H >3.5Q <14.21/ETOC20.61052 | 0 | 0 | 0 | 0 | 8
14.2≤Q ≤18.81/ETOC18.84466 | 0.26742Q | −0.200440Q0.88 | 0 | 0.01025Q0.5 | 9
18.8<Q ≤6991/ETOC19.66658 | 0.26742Q | −0.253320Q0.88 | 0 | 0.01025Q0.5 | 10
699<Q ≤14001/ETOC39.19213 | 0.29062Q | −0.253320Q0.88 | 0 | 0.01449Q0.5 | 11
1400<Q ≤21001/ETOC58.71768 | 0.30511Q | −0.253320Q0.88 | 0 | 0.01775Q0.5 | 12
2100<Q ≤28001/ETOC78.24323 | 0.31582Q | −0.253320Q0.88 | 0 | 0.02049Q0.5 | 13
2800<Q ≤35001/ETOC97.76879 | 0.32439Q | −0.253320Q0.88 | 0 | 0.02291Q0.5 | 14
No0≤H ≤0.48Q <14.21/ETOC11.0125 | 0 | 0 | −0.17109QH | 0 | 15
14.2≤Q ≤13401/ETOC8.54245 | 0.10555Q | 0.090300Q0.88 | −0.17109QH | 0.01025Q0.5 | 16
1340<Q ≤26901/ETOC16.94386 | 0.11470Q | 0.090300Q0.88 | −0.17109QH | 0.01449Q0.5 | 17
2690<Q ≤40401/ETOC25.34528 | 0.12042Q | 0.090300Q0.88 | −0.17109QH | 0.01775Q0.5 | 18
0.48<H ≤1.9Q <14.21/ETOC13.4563 | 0 | 0 | −0.16181QH | 0 | 19
14.2≤Q ≤13401/ETOC9.25233 | 0.06105Q | 0.319370Q0.88 | −0.16181QH1 | 0.01025Q0.5 | 20
1340<Q ≤26901/ETOC18.36363 | 0.06635Q | 0.319370Q0.88 | −0.16181QH | 0.01449Q0.5 | 21
2690<Q ≤40401/ETOC27.47492 | 0.06965Q | 0.319370Q0.88 | −0.16181QH | 0.01775Q0.5 | 22
1.9<H ≤3.6Q <14.21/ETOC7.96988 | 0 | 0 | 0 | 0 | 23
14.2≤Q ≤11801/ETOC6.67868 | 0.06943Q | 0.025820Q0.88 | 0 | 0.01025Q0.5 | 24
1180<Q ≤23701/ETOC13.21633 | 0.07546Q | 0.025820Q0.88 | 0 | 0.01449Q0.5 | 25
2370<Q ≤35501/ETOC19.75398 | 0.07922Q | 0.025820Q0.88 | 0 | 0.01775Q0.5 | 26
H >3.6Q <14.21/ETOC6.67868 | 0 | 0.02220Q0.88 H0.88 | −0.00707QH | 0.02036H0.5 | 27
Q ≥14.2 and14.2≤Q*(H/3.6) ≤11801/ETOC6.67868 | 0 | 0.02220Q0.88 H0.88 | −0.00707QH | 0.00540Q0.5 H0.5 | 28
Q ≥14.2 and1180<Q*(H/3.6) ≤23701/ETOC13.21633 | 0 | 0.02412Q0.88 H0.88 | −0.00707QH | 0.00764Q0.5 H0.5 | 29
Q ≥14.2 and2370<Q*(H/3.6) ≤35501/ETOC19.75398 | 0 | 0.02533Q0.88 H0.88 | −0.00707QH | 0.00936Q0.5 H0.5 | 30
No0≤H <11.2All1/ETOC2.08 | 2.25Q | 0.288Q0.8 | −0.193QH | −0.0051ETOC | 31
H ≥11.2All1/ETOC2.08 | 0.309Q | 0.0619Q0.8 | −0.0043QH | −0.0043ETOC | 32

a Use according to procedures outlined in § 65.64(h).

b MJ/scm = mega Joules per standard cubic meter.

c scm/min = standard cubic meters per minute.